ZK-XMJA intelligent flow totalizer is used with various flow sensors or transmitters, temperature sensors or transmitters and pressure transmitters. The intelligent flow totalizer can be used for various liquids, steam, natural gas, general gas, etc. The flow parameters are used for measurement display, cumulative calculation, alarm control, transmission output, data acquisition and communication.

●Features

Intelligent flow totalizer full range of automatic temperature and pressure compensation calculation, compensation mode arbitrarily set linear total calculation, open square calculation, arbitrary setting instantaneous flow, cumulative flow, temperature, pressure, various parameters, display small signal cutting function, cutting range The 0-5% optional cumulative flow value can be cleared by the panel button. The clear operation can lock the power protection function. The accumulated flow value is reduced for more than 5 years. All the set values ​​are permanently maintained after the power is turned off. Structure, with powerful instrument chip, functional combination, system upgrade is very convenient

●Main technical indicators

Basic error: 0.5% FS or 0.2% FS±1 word resolution: 1/20,000, 14-bit A/D converter display mode: double-row simultaneous display, upper row of four digital tubes display instantaneous flow, lower row eight Digital tube shows cumulative flow sampling period: 0.5S
Alarm output: instantaneous flow two limit alarm, relay output contact capacity AC220V/3A
Transmission output: 4~20mA, 0~10mA, 1~5V, 0~5V Accuracy: ±0.3%FS
Communication output: interface mode--isolated serial two-way communication interface RS485/RS422/RS232/Modem
Baud rate - 300 ~ 9600bps internal free set feed output: DC24V / 50mA
Power supply: switching power supply 85 ~ 265VAC power consumption below 4W

● Model description

Type spectrum Description
ZK-XMJA
Dimensions A Horizontal type 160×80×125mm
A/S Vertical type 80×160×125mm
B Mode 96×96×110mm
Control output B0 B0 has no alarm output, can be omitted
B1 Instantaneous flow upper limit alarm
B2 Instantaneous flow lower limit alarm
B3 Instantaneous flow upper and lower limit alarm
B4 Cumulative flow limit alarm
B5 Cumulative flow lower limit alarm
B6 Cumulative flow upper and lower limit alarm
Transmitting output X1 4-20mA output
X2 0-10mA output
X3 1-5V output
X4 0-5V output
Communication output P Micro printer
R Serial communication RS232
S Serial communication RS485
Transmitter power distribution No feed output
V12 With DC12V feed output
V24 With DC24V feed output
Power supply 220VAC power supply
W DC24V power supply
Flow input signal L1 Current: 4-20mA, 0-10mA, 0-20 mA
L2 Voltage: 1-5V, 0-5V
L3 Pulse frequency: 0-10KHZ
Temperature input signal W1 Current: 4-20mA, 0-10mA, 0-20mA
W2 Voltage: 1-5V, 0-5V
W3 Thermal resistance: Pt100
W4 Thermocouple: K, T, E
Pressure input signal Y1 Current: 4-20mA, 0-10mA, 0-20mA
Y2 Voltage: 1-5V, 0-5V

Model example: ZK-XMJA-AB3X1SV24L1W1Y1
ZK-XMJA series , External dimensions 160×80×125mm, instantaneous flow upper and lower limit alarm control output, 4~20mA instantaneous flow signal input, 4~20mA pressure signal input, 4~20mA temperature signal input, 4~20mA instantaneous flow transmission output, with RS485 Isolated communication interface with DC24V feed output, power supply 220VAC