First, the double-layer glass reactor material Description The borosilicate glass has a coefficient of expansion of 3.3, a glass containing sodium oxide (Na2O), boron oxide (B2O3), and silicon dioxide (SiO2) as the basic components. The borosilicate content of the glass component is relatively high, and is boron: 12.5 to 13.5%, and silicon: 78 to 80%. Therefore, this type of glass is called borosilicate glass. It belongs to the Pyrex glass in borosilicate glass. The utility model is characterized in that the thermal expansion coefficient is small, and it is not easy to burst under the sudden change of temperature at high temperature; acid and alkali resistance, water resistance, superior corrosion resistance, good thermal stability, chemical stability and electrical properties, so it has chemical resistance and resistance. It is also known as heat-resistant glass, heat-resistant impact glass, high-temperature resistant glass, and is also a special fireproof glass because of its thermal shock resistance, good mechanical properties, high temperature and high hardness.
The main parameters are as follows:
1. Withstand voltage test: Water pressure test is carried out on pipe fittings such as "glass pipe straight pipe" or "elbow" with a diameter of 2 inches or less. When pressurized to 4kg/cm2, no damage is allowed, in order to retain sufficient Safety factor, the use pressure should not exceed 2kg/cm2.
In order to retain a sufficient safety factor, the reactor or condenser and some thin-walled products should not be used at a pressure of more than 2 kg/cm2. 2. Water resistance: Take a glass powder sample with a particle diameter of 0.3-0.5 mm and boil it with distilled water. The amount of Na2O precipitated was measured at 1 hour, and the amount per gram of the sample was not more than 0.003 mg.
3. Acid resistance: The glass sample was boiled in hydrochloric acid with a content of 20.4% for 3 hours to measure the weight loss, and the calculation was not more than 0.7 mg per 100 cm 2 of surface area.
4. Anti-alkali performance: The glass sample is boiled in a mixed solution of 1 equivalent of NaOH and 1 equivalent of Na2CO3 for three hours, and the weight loss is measured, and the calculation is not more than 90 mg per 100 cm 2 of surface area.
5, melting temperature: 1680 ° C, molding temperature: 1260 ° C, softening temperature: 830 ° C, annealing temperature: 560 ° C
Technical parameters for double-layer glass reactor:
1.) Reactor, double-layer design, GG17 borosilicate glass material, intermediate jacket can be heated into high temperature reaction (Zui high temperature can reach 315 ° C, solvent generally uses kinematic viscosity of 100; flash point is 320 °C dimethyl silicone oil,); the middle jacket can also be passed into the cold solvent for low temperature constant temperature reaction (zui low temperature can reach -80 ° C); the high borosilicate glass produced by our factory has proved that it can accept large temperature difference changes. The design of the interlayer has a good thermal insulation effect and is a good choice for constant temperature reaction.
2.) The opening on the glass body of our factory is 265mm large diameter design, which is very convenient for cleaning. The lower discharge material is designed to be PTFE detachable, which facilitates the smooth release of solid and granules and reaction materials with large viscosity.
3.) Double-layer glass reactor adopts high-power stirring motor, stepless speed regulation, stirring torque is 15000g.cm (speed is 780/min); stirring rod is stainless steel inner core, outside is tetrafluoroplastic;
4. The lid is designed for five standard ports. Double-layer glass reactor lid opening: 50# (stirring), 40# (condensing), 40# (feeding), 34# (standby), 24# (temperature measurement) ) the opening. The opening can be customized according to the user's needs. 5.) Description of the pressure resistance of the kettle body: The laboratory can generally measure the pressure resistance of borosilicate glass to 0.8kg/cm. The vacuum degree that can be achieved inside the kettle body is -0.098MPA. Can meet high experimental requirements.
6.) The stirring speed of the machine is 0-780r/min, which can be adjusted, and the speed is digital, which is convenient for observing the reaction of the material. Thereby adjusting the speed of stirring.
7.) The thickness of GG17 borosilicate glass is 7mm. All openings are standard lip flanges.
8.) The complete set of reaction kettles are equipped with stirring, distillation and reflux functions; they can be reacted under vacuum, distilled and refluxed.
9.) High-temperature reaction device, the outlet is connected to the lower port of the reaction kettle, and the upper reflux is connected to the lower opening.
Second, the high-temperature equipment associated with it:
GCS series high temperature circulating oil baths are widely used for distillation, drying, concentration and impregnation of chemicals or biological products. It is an ideal tool for laboratory testers in environmental protection, scientific research, health, epidemic prevention, petroleum, metallurgy, chemical, medical and other institutions.
The instrument has an external circulation function and is a good device for providing heat sources for rotary evaporators, double-layer glass reactors, centrifugal pumps and the like.
B), performance:
1, power: 220V ± 10V50Hz
2, temperature control range: 0 ° C ~ 200 ° C ± 1 ° C
3, temperature fluctuation: ≤ 1 ° C
C), usage:
This instrument uses 220V AC voltage, please make sure that the power outlet has a rated current of not less than 15A before use and has a safety grounding device.
When using, it is necessary to first add oil to the pot to at least submerge the heating tube.
First turn on the power, the red number on the top and bottom of the meter is displayed. After 30 seconds of rest, the upper row shows the actual water/oil temperature. Press the /SET button, the upper row displays SP, press the â–² or â–² button to make the lower row display as Press the /SET button, press the /SET button, the upper display will display ST, and still press the /SET button to return to the upper row to display the actual temperature. At this time, after a few seconds, the smart watch will start to work. The instrument starts working normally.
If you want to change the set temperature, such as resetting the higher temperature (or the original set temperature error is too large), press /SET button, the upper row displays SP, press â–² or â–² button to make the lower row display as The required temperature, press / SET button, the upper row shows ST, still press / SET button, the upper row shows the actual temperature. At this time, press and hold the /AT button for 20 seconds, the RUN light will flash, the meter will start self-tuning, and it will be automatically back and forth (refer to stop heating when the temperature is automatically raised to the set temperature, and start heating when it is lower than the set temperature). After the self-adjustment is finished, the RUN light is off, and the meter also obtains a set of parameters that can never overcome the over-temperature.
The main parameters are as follows:
1. Withstand voltage test: Water pressure test is carried out on pipe fittings such as "glass pipe straight pipe" or "elbow" with a diameter of 2 inches or less. When pressurized to 4kg/cm2, no damage is allowed, in order to retain sufficient Safety factor, the use pressure should not exceed 2kg/cm2.
In order to retain a sufficient safety factor, the reactor or condenser and some thin-walled products should not be used at a pressure of more than 2 kg/cm2. 2. Water resistance: Take a glass powder sample with a particle diameter of 0.3-0.5 mm and boil it with distilled water. The amount of Na2O precipitated was measured at 1 hour, and the amount per gram of the sample was not more than 0.003 mg.
3. Acid resistance: The glass sample was boiled in hydrochloric acid with a content of 20.4% for 3 hours to measure the weight loss, and the calculation was not more than 0.7 mg per 100 cm 2 of surface area.
4. Anti-alkali performance: The glass sample is boiled in a mixed solution of 1 equivalent of NaOH and 1 equivalent of Na2CO3 for three hours, and the weight loss is measured, and the calculation is not more than 90 mg per 100 cm 2 of surface area.
5, melting temperature: 1680 ° C, molding temperature: 1260 ° C, softening temperature: 830 ° C, annealing temperature: 560 ° C
Technical parameters for double-layer glass reactor:
1.) Reactor, double-layer design, GG17 borosilicate glass material, intermediate jacket can be heated into high temperature reaction (Zui high temperature can reach 315 ° C, solvent generally uses kinematic viscosity of 100; flash point is 320 °C dimethyl silicone oil,); the middle jacket can also be passed into the cold solvent for low temperature constant temperature reaction (zui low temperature can reach -80 ° C); the high borosilicate glass produced by our factory has proved that it can accept large temperature difference changes. The design of the interlayer has a good thermal insulation effect and is a good choice for constant temperature reaction.
2.) The opening on the glass body of our factory is 265mm large diameter design, which is very convenient for cleaning. The lower discharge material is designed to be PTFE detachable, which facilitates the smooth release of solid and granules and reaction materials with large viscosity.
3.) Double-layer glass reactor adopts high-power stirring motor, stepless speed regulation, stirring torque is 15000g.cm (speed is 780/min); stirring rod is stainless steel inner core, outside is tetrafluoroplastic;
4. The lid is designed for five standard ports. Double-layer glass reactor lid opening: 50# (stirring), 40# (condensing), 40# (feeding), 34# (standby), 24# (temperature measurement) ) the opening. The opening can be customized according to the user's needs. 5.) Description of the pressure resistance of the kettle body: The laboratory can generally measure the pressure resistance of borosilicate glass to 0.8kg/cm. The vacuum degree that can be achieved inside the kettle body is -0.098MPA. Can meet high experimental requirements.
6.) The stirring speed of the machine is 0-780r/min, which can be adjusted, and the speed is digital, which is convenient for observing the reaction of the material. Thereby adjusting the speed of stirring.
7.) The thickness of GG17 borosilicate glass is 7mm. All openings are standard lip flanges.
8.) The complete set of reaction kettles are equipped with stirring, distillation and reflux functions; they can be reacted under vacuum, distilled and refluxed.
9.) High-temperature reaction device, the outlet is connected to the lower port of the reaction kettle, and the upper reflux is connected to the lower opening.
Second, the high-temperature equipment associated with it:
GCS series high temperature circulating oil baths are widely used for distillation, drying, concentration and impregnation of chemicals or biological products. It is an ideal tool for laboratory testers in environmental protection, scientific research, health, epidemic prevention, petroleum, metallurgy, chemical, medical and other institutions.
The instrument has an external circulation function and is a good device for providing heat sources for rotary evaporators, double-layer glass reactors, centrifugal pumps and the like.
B), performance:
1, power: 220V ± 10V50Hz
2, temperature control range: 0 ° C ~ 200 ° C ± 1 ° C
3, temperature fluctuation: ≤ 1 ° C
C), usage:
This instrument uses 220V AC voltage, please make sure that the power outlet has a rated current of not less than 15A before use and has a safety grounding device.
When using, it is necessary to first add oil to the pot to at least submerge the heating tube.
First turn on the power, the red number on the top and bottom of the meter is displayed. After 30 seconds of rest, the upper row shows the actual water/oil temperature. Press the /SET button, the upper row displays SP, press the â–² or â–² button to make the lower row display as Press the /SET button, press the /SET button, the upper display will display ST, and still press the /SET button to return to the upper row to display the actual temperature. At this time, after a few seconds, the smart watch will start to work. The instrument starts working normally.
If you want to change the set temperature, such as resetting the higher temperature (or the original set temperature error is too large), press /SET button, the upper row displays SP, press â–² or â–² button to make the lower row display as The required temperature, press / SET button, the upper row shows ST, still press / SET button, the upper row shows the actual temperature. At this time, press and hold the /AT button for 20 seconds, the RUN light will flash, the meter will start self-tuning, and it will be automatically back and forth (refer to stop heating when the temperature is automatically raised to the set temperature, and start heating when it is lower than the set temperature). After the self-adjustment is finished, the RUN light is off, and the meter also obtains a set of parameters that can never overcome the over-temperature.