Features:
1. 4.3" color TFT LCD screen (LED backlight), with resolution 272×480
2. Three working modes: Rate/Time/Volume mode
3. Drug library with 210 kinds of medicine
4. Storage 1500 history records
5. Heating function, suitable for infusing in winter or there is requirement for the fluid medication temperature
6. Support multi language display
7. A variety of visible and audible alarm, make infusion more safe


Â
Large LCD display, with backlight, suitable for working in various ambient light conditions. |
Disposable IV set of any brand is suitable for this pump |
Three working modes: Rate/Volume/Time mode |
Purge, KVO function |
Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature. |
Remote Controller makes operating more convenient. |
Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission. |
Simple and convenient in operating, intuitive presence of working status. |
Audible and Visible alarms |
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
Size: 188 mm(L)*198 mm(W)*228 mm(H) |
Net Weight: 2.2kg |
Standard:Drug library, History record, Heating function, Drip detector
Optional:SpO2,NIBP
Why we add NIBP &SpO2 to an infusion pump?
NIBP & SpO2 are the most frequently used vital sign parameters, we make them work as one, to help doctors reduce cost and save space which is already very limited in the hospital room.



Technical data sheet: Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
Pump Type |
Drip type infusion pump |
Pumping Way |
Peristalic fingers |
Adjustable Drop Rate Range |
1~400 drops/min (step: 1 drop/min) |
Adjustable Volume Rate Range |
1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h) |
Flow Precision |
Within 3% more or less(using the IV set appointed by the manufacturer or calibrated high quality IV set) |
Mechanical precision |
within 2% more or less |
Purge Rate |
800 ml/h |
KVO Rate |
1 ml/h (1~300 ml/h) 3 ml/h (greater than 300 ml/h) |
Infusion Volume Range |
1 ml~9999.9 ml (step: 0.1 ml) |
Maximum Accumulated Volume |
9999.9 ml (step: 0.1 ml) Â |
Time Range |
1 min~9999 min (step: 1 min) |
Occlusion Alarm Threshold |
High: 800 mmHg+-200 mmHg (106.7kPa+-26.7kPa) Medium: 500 mmHg+-100 mmHg (66.7kPa+-13.3kPa) Low: 300 mmHg+-100 mmHg (40.7kPa+-13.3kPa) |
Alarm |
Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
Air Bubble Detector Method |
ultrasonic wave, sensitivity: more than or equal 25 μL |
Fuse |
F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity), 2 pcs (installed inside pump). |
Power Supply |
AC 85~265V, 50/60Hz; |
Internal Battery |
11.1V rechargeable li-ion battery. Capacity:more than or equal 2000mAh; the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for 8 hours (Medium rate specified by GB 9706.27-2005). |
Power |
less than or equal 40VA |
Size |
188 mm(L)*198 mm(W)*228 mm(H) |
Weight |
2.2KG |
Environment Requirements |
Transport Ambient Temperature: -30°C~+55°C Relative Humidity: 20%~95% (non-condensing) Atmosphere Pressure: 70kPa~106kPa Storage Ambient Temperature: -30°C~+55°C Relative Humidity: 20%~95% Atmosphere Pressure: 70kPa~106kPa Operation Ambient Temperature: +5~+40°C Relative Humidity: 20%~90% Atmosphere Pressure: 86kPa~106kPas |
Calibration function |
disposable IV set of any brand is suitable for this pump |
Three working modes |
Rate/Volume/Time mode |
Alarm |
Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
infusion monitoring system (Optional), the status of each pump is displayed in real time at the central station through wireless transmission. | |
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions. | |
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication |
Technical Specification:
Infusion rate range
Adjustable drop rate range: 1 /min~400 drops/min
                         (step: 1 drop /min)
Adjustable flow rate range: 1ml/h~1200ml/h
                        (step 0.1ml/h)
Purge rate: 800ml/h
KVO rate: 1ml/h (1~300ml/h)
        3ml/h (greater than 300ml/h)
Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
Infusion Time range: 1min~9999min (step: 1 min)
Infusion accuracy: Within ±3% (using calibrated high quality IV set)
                  Mechanical precision: within ±2%
Occlusion alarm threshold:
        High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
NIBP
Range
Average deviation: ≤ ±5mmHg
Standard deviation: ≤ 8mmHg
Adult
        SYS: 40mmHg~280mmHg
        MEAN: 20mmHg~240mmHg
        DIA: 10mmHg~220mmHg
Pediatric
        SYS: 40mmHg~220mmHg
        MEAN: 20mmHg~170mmHg
        DIA: 10mmHg~160mmHg
Neonate
        SYS: 40mmHg~135mmHg
        MEAN: 20mmHg~110mmHg
        DIA: 10mmHg~100mmHg
Static pressure
        Range: 0mmHg~300mmHg
        Deviation: 3mmHg
Resolution: 1mmHg
NIBP measurement mode
Manual
Cycle (automatic):
Optional interval: 1min, 2min, 3min,4min, 5min, 10min,
15min, 30min, 60min, 90min
Fast: continuous NIBP measurement, interval is 5min
NIBP alarm
High pressure alarm: >90mmHg-160mmHg
Low pressure alarm: <50mmHg-90mmHg
Accuracy: ±5%
Overpressure protection
Adult: 280 mmHg ±10 mmHg
Pediatric: 237 mmHg ±3 mmHg
Neonate: 147 mmHg ±3 mmHg
SpO2
Range: 0%~100%
Resolution: 1%
Accuracy: 70% to 100%, precision is 2%
         0% to 69%, undefined
SpO2 alarm
Upper limit: 100%
Lower limit: 90%
Alarm value accuracy: 3%
Alarm time accuracy: 2s
Pulse rate
Range: 20bpm~300bpm
Resolution: 1bpm
Accuracy: 3bpm
Pulse rate alarm
Upper limit: 120bpm
Lower limit: 50bpm (default)
Alarm value accuracy: 5%
Alarm time accuracy: 2s
NIBP Cuff requirement
Human body contact materials: Waterproof cloth
Size: 515mm(L)×145mm(W), allowed deviation: ±5%
SpO2 sensor
Type: Finger clip type
Wire length: 3000mm, allowed deviation: ±5%
Human body contact materials: Silicone
Size: 188 mm(L)×198 mm(W)×228 mm(H)
Net weight: 2.2kg
Why choose us:
we got production and business certification from Chengdu food and Drug Administration
we got business license from Chengdu City Administration of industry and commerce
we got products certificate of registration and have checked in the website of SFDA
we have accepted the onsite check from SFDA every quarter
we finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;
Â
1. Maca Extract can be applied in pharmaceutical field.
(1) Maca Extract can promote libido and sexual function.
(2) Maca Extract can support the glandular system.
2. Maca Extract can be applied in health care products.
(1) Maca Extract can promote mental clarity and concentration,Increases libido and improves sperm quality
(2) Maca Extract owns the effect on supporting stamina and buffers the effects of stress.
(3) Maca Extract can boost work capacity.
Our company offers variety of products which can meet your multifarious demands.including API Powder.Pharmaceutical Intermediates.Vitamins Powder.Plant Extracts.Food Additive.Peptide Powder and so on We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.
1. Maca Extract can be applied in pharmaceutical field.
(1) Maca Extract can promote libido and sexual function.
(2) Maca Extract can support the glandular system.
2. Maca Extract can be applied in health care products.
(1) Maca Extract can promote mental clarity and concentration,Increases libido and improves sperm quality
(2) Maca Extract owns the effect on supporting stamina and buffers the effects of stress.
(3) Maca Extract can boost work capacity.
Our company offers variety of products which can meet your multifarious demands.including API Powder.Pharmaceutical Intermediates.Vitamins Powder.Plant Extracts.Food Additive.Peptide Powder and so on We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.
Application
1.Applied in food field, maca extract is used as an anti-aging food,butt enhancement;
2.Applied in health food field, maca extract is also used as an afrodyn;
3.Applied in pharmaceutical field, maca extract is used to treat organ dysplasia,premature ejaculation and male impotence
2.Applied in health food field, maca extract is also used as an afrodyn;
3.Applied in pharmaceutical field, maca extract is used to treat organ dysplasia,premature ejaculation and male impotence
Name
|
Maca Extract
|
Active Ingredient
|
Maca Extract
|
Appearance
|
powder
|
Grade
|
Food Grade
|
Storage
|
Cool Dry Place
|
product Photo:
Plant Extract Powder,Maca Root Extract,Resveratrol Powder,Calcitriol Powder
Shaanxi YXchuang Biotechnology Co., Ltd , https://www.peptidenootropics.com